Automotive Diagnostic USB Oscilloscope Multimeter

2 Channel
$266.00
Qty:

Automotive Diagnostic USB Oscilloscope Multimeter 80MHz 4 in 1 automatic measuring

  it continues the compact and lightweight concept but with a new generation of 4 in 1 multifunction tester: Automotive Diagnostic, oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.

Accessories List

 

  • 2D82I: Device 2D82*1, Package Toolcase*1, Type C cable*1, Power Adaptor*1, Multimeter Probe*1, Test Leads with BNC plug and alligator clip-HT324*2, Auto Test Leads-HT30B*1, Auto Ignition Probe-HT25*1, Acupuncture Probe Set-HT307*1, Coil-on-Plug extension cord-HT308*1, 20:1 Attenuator-HT201*1

 

  • 2D82II: Device 2D82*1, Package Toolcase*1, Type C cable*1, Power Adaptor*1, Multimeter Probe*1, Test Leads with BNC plug and alligator clip-HT324*2, Auto Test Leads-HT30B*2, Auto Ignition Probe-HT25*2, Acupuncture Probe Set-HT307*1, Coil-on-Plug extension cord-HT308*2, 20:1 Attenuator-HT201*2, Large Dolphin/Gator Clips-HT18A*1, 6 Way Breakout Leads-HT306-2.8mm*1、1.5mm*1

 

  • 2D82III: Device 2D82*1, Package Toolcase*1, Type C cable*1, Power Adaptor*1, Multimeter Probe*1, Test Leads with BNC plug and alligator clip-HT324*2, Auto Test Leads-HT30B*2, Auto Ignition Probe-HT25*2, Acupuncture Probe Set-HT307*2, Coil-on-Plug extension cord-HT308*2, 20:1 Attenuator-HT201*2, Large Dolphin/Gator Clips-HT18A*2, 6 Way Breakout Leads-HT306-2.8mm*1、1.5mm*1、1.0mm*1、2.3mm*1, Breakout Leads-HT301*1, 65A AC/DC Current Clamp-CC65*1, 650A AC/DC Current Clamp-CC650*1

Parameters

Bandwidth80MHz
Channel2CH DMM AWG
Sample Rate Range250MSa/s(Single-channel), 125MSa/s(Dual-channel)
Waveform Interpolation(sin x)/x
Record Length3K samples per dual-channel
SEC/DIV Range5ns/div~500s/div 1, 2, 5 sequence
A/D Converter8-bit resolution,each channel sampled simultaneously
VOLTS/DIV Range10mV/div~10V/divat input BNC
Bandwidth Limit, typical20MHz
Low Frequency Response (-3db)≤10Hz at BNC
Rise Time at BNC, typical≤5ns
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
Waveform FrequencySine: 1Hz~25MHz;Square: 1Hz~10MHz;Ramp: 1Hz~1MHz;EXP: 1Hz~5MHz
Sampling250MSa/s
Vertical Resolution12 bit
Frequency Resolution0.001
  • Availability: In Stock
  • Model: 2D82-I